Distributor for 25+ Global Partners
+91-22-40030990 +91-22-68286323 info@polytechinstruments.com
Type at least 2 characters, or press Enter to see all matching products
Labtron Equipment Ltd

Ion Chromatograph LPIC_A10

Analytical Equipment

Ion Chromatograph LPIC-A10 is a light weight, portable design model with powerful data processing system. The quick ion chromatograph columns are used for rapid 5 min detection.

Full Description

Ion Chromatograph LPIC-A10 is a light weight, portable design model with powerful data processing system. The quick ion chromatograph columns are used for rapid 5 min detection. Adopted with built –in multi-channel solvent selection valve helps in gradient elusion, it shortens peak time, and improves efficiency of the chromatograph conducted. Upgraded with dual detection system (dual column for various applications), supports the needs of different industries.

Features

  • Built-in column temperature control box for accurate experimental results
  • Capable with Flash column for rapid detection of anions and cations
  • Intelligent flow path clearing system for easy cleaning
  • Real time display
  • Wi-Fi connection for convenient data transfer
  • Continuous, non-stop 10 hours working system
  • Easy to operate

Applications

Used for on field selective analysis of organic and inorganic ions, also used in quality and research laboratories across pharmaceutical, water quality, chemical industries.

Specifications

Chromatographic PumpType High-pressure and low –pulse double plunger tandem advection pump Maximum Pressure 35 MPa (PEEK) Flow Range 0.001 to 9.999 mL/min Flow accuracy ± 0.5 % Flow Repeatability RSD ≤ 0.1% Flow stability (0.2 to 0.5) mL/min, ≤ 3 % (0.5 to 1.0) mL/min, ≤ 2 % >1.0 mL/min, ≤ 2 %TypeHigh-pressure and low –pulse double plunger tandem advection pumpMaximum Pressure35 MPa (PEEK)Flow Range0.001 to 9.999 mL/minFlow accuracy± 0.5 %Flow RepeatabilityRSD ≤ 0.1%Flow stability(0.2 to 0.5) mL/min, ≤ 3 % (0.5 to 1.0) mL/min, ≤ 2 % >1.0 mL/min, ≤ 2 %
TypeHigh-pressure and low –pulse double plunger tandem advection pump
Maximum Pressure35 MPa (PEEK)
Flow Range0.001 to 9.999 mL/min
Flow accuracy± 0.5 %
Flow RepeatabilityRSD ≤ 0.1%
Flow stability(0.2 to 0.5) mL/min, ≤ 3 % (0.5 to 1.0) mL/min, ≤ 2 % >1.0 mL/min, ≤ 2 %
Built-in Heat conduction type column heaterTemperature range Room temperature +5°C to 60°C (41 to 140°F) Allowable deviation ± 1°C Temperature stability ≤ 0.5°C/hTemperature rangeRoom temperature +5°C to 60°C (41 to 140°F)Allowable deviation± 1°CTemperature stability≤ 0.5°C/h
Temperature rangeRoom temperature +5°C to 60°C (41 to 140°F)
Allowable deviation± 1°C
Temperature stability≤ 0.5°C/h
Electromagnetic injection valveMaximum pressure 35 MPa Control mode By stepper motor Power supply 24 V (DC)Maximum pressure35 MPaControl modeBy stepper motorPower supply24 V (DC)
Maximum pressure35 MPa
Control modeBy stepper motor
Power supply24 V (DC)
Digital and temperature control detection systemType Temperature control and bipolar conductivity detector Detection type Bipolar conductivity detection Cell volume ≤ 0.8 µL Measurement range 0 to 45000 µ S/cm (adjustable) Detection resolution ≤ 0.0020 nS/cm Output voltage -6000 to 6000 mV (adjustable) Temperature range Room temperature +5°C to 6TypeTemperature control and bipolar conductivity detectorDetection typeBipolar conductivity detectionCell volume≤ 0.8 µLMeasurement range0 to 45000 µ S/cm (adjustable)Detection resolution≤ 0.0020 nS/cmOutput voltage-6000 to 6000 mV (adjustable)Temperature rangeRoom temperature +5°C to 60°C (41 to 140°F)Temperature accuracy± 0.01°CMaximum pressure10 MPaBaseline drift≤ 20 % FS/30 minBaseline noise≤0.5 % FSInstrument linearity≥ 0.999Quantitative Repeatability≤0.5 %Qualitative Repeatability≤2 %Minimum detectable concentrationCl-≤0.005 µg/mL Li+ ≤0.005 µg/mL
TypeTemperature control and bipolar conductivity detector
Detection typeBipolar conductivity detection
Cell volume≤ 0.8 µL
Measurement range0 to 45000 µ S/cm (adjustable)
Detection resolution≤ 0.0020 nS/cm
Output voltage-6000 to 6000 mV (adjustable)
Temperature rangeRoom temperature +5°C to 60°C (41 to 140°F)
Temperature accuracy± 0.01°C
Maximum pressure10 MPa
Baseline drift≤ 20 % FS/30 min
Baseline noise≤0.5 % FS
Instrument linearity≥ 0.999
Quantitative Repeatability≤0.5 %
Qualitative Repeatability≤2 %
Minimum detectable concentrationCl-≤0.005 µg/mL Li+ ≤0.005 µg/mL
Flow systemPlastic path flow Made of PEEK material Six way valve PEEK material pressure 5000 psi, independent automatic collecting and flow functionPlastic path flowMade of PEEK materialSix way valvePEEK material pressure 5000 psi, independent automatic collecting and flow function
Plastic path flowMade of PEEK material
Six way valvePEEK material pressure 5000 psi, independent automatic collecting and flow function
Panel computerDisplay screen 12.3 inch Internal memory 2G Weight 786 gDisplay screen12.3 inchInternal memory2GWeight786 g
Display screen12.3 inch
Internal memory2G
Weight786 g
External size (L × W × H)440 × 226 × 420 mm
Net weight8 kg
Gross weight11 kg

Downloads

More from Labtron Equipment Ltd

View all Labtron Equipment Ltd products →