ISOBARIC-404 Oxygen Transmission Rate Tester
ISOBARIC-404 Oxygen Transmission Rate Tester is designed and manufactured according to ASTM D3985 and other standards, and is suitable for testing the oxygen transmission rate of high and medium oxygen and air barrier materials.
Full Description
It is suitable for testing the oxygen transmission rate of films, sheets, containers and related materials in the fields of food, pharmaceuticals, medical devices, daily chemicals, photovoltaics, electronics, industrial products, etc.
Characteristics
1. High-precision coulometric oxygen sensor improves test accuracy and stability
2. Four test chambers are completely independent of each other, allowing simultaneous testing of four identical or different specimens.
3. One chamber is used as a reference chamber to determine the accuracy of the standard membrane data.
4. Three test chambers are used to test samples, ensuring that three parallel samples can be tested at one time
5. Wide-range, high-precision, automated temperature and humidity control to meet a variety of test conditions.
6. Unique test structure, four chambers under the same temperature and humidity for testing, to ensure the consistency of the test conditions of different test chambers.
7. Test results support multi-format storage and data output, including lab reports Excel, cloud sharing
8. Statistical analysis of test results can be carried out for single and grouped tests
9. With ISP online control, upgrade function, can be required to change the test function remotely
10. Specialized computer communication software, real-time display of the test and data analysis and processing, data preservation
Principle
The treated sample is clamped onto the test chamber.
Oxygen or air flows on one side of the film and high purity nitrogen flows on the other side of the film.
Oxygen molecules diffuse through the film into the high purity nitrogen in the other side and are carried by the flowing nitrogen to the sensor, which analyses the oxygen concentration measured by the sensor and produces oxygen transmission rate test data after reaching permeation equilibrium.
Technical Indexes
Test Parameters (Film)
Parameter/Model ISOBARIC-404
Measurement range cc/(m2day) (standard area 50cm2) 0.02 ~ 200
Resolution cc/(m2day) 0.01
Humidity Range RH% (Standard Temperature Range) 0%, 5 ~ 90%±1
Temperature Range ℃ 20 ~ 50
Temperature Resolution ℃ 0.1
Specifications
| Test chambers | 4 |
|---|---|
| Sample size | 97 mm × 97 mm Other sizes can be customized. |
| Sample thickness | ≤ 3 mm |
| Standard test area | 50 cm² |
| Test Gas | 99.5% Oxygen (user-provided gas source) |
| Carrier gas | 99.999% high purity nitrogen |
| Test Pressure | 7.2 PSI / 50 kPa |
| Connection Size | 1/8 inch metal pipe |
| Dimensions | 440 mm (L) × 450 mm (W) × 450 mm (H) |
| Power supply | AC 220V 50Hz |