LD-GPT-03 Gas Permeability Tester
Gas Permeability Tester is applicable in the measurement of gas permeability rate, solubility coefficient, diffusion coefficient and permeability coefficient at various temperature of plastic films, laminated films, high barrier material, sheets, foils, and etc.
Full Description
Characteristics
It can measure the gas permeability and gas permeability coefficient of the sample at the same time.
It can meet the completely independent test of three test chambers
Wide range, high precision temperature and humidity control, meet various test conditions test
Provide three test process judgments of proportional, fuzzy mode and time mode model
The test range can be expanded as needed to meet the requirements of high transmittance test Support the test of toxic gas and flammable and explosive gas (customized)
Pneumatic clamping sample, convenient and fast The system adopts electronic intelligent control, and the whole test process is completed automatically
Provide standard film for quick calibration to ensure the accuracy of test data
The product conforms to GMP three-level authority Micro-printer, note to print test statistical results at any time
Special computer communication software, which can perform real-time display of the test, analysis and processing of data, and data storage
Equipped with USB universal data interface, convenient for data transmission
Principle
Put the pre-conditioned specimen between the upper chamber and chamber, clamp it tightly. First vacuumize the low-pressure chamber (lower chamber), and then the whole system. When the specified degree of vacuum is achieved, shut off the lower test chamber and feed test gas to the upper test chamber (high pressure chamber) until certain pressure is reached. Ensure that a constant differential pressure (adjustable) is maintained across the specimen. Hence under the gradient of differential pressure the test gas permeates from the high-pressure side to the low-pressure side. By monitoring and measuring the pressure in the low-pressure side we can get various barrier parameters of the tested specimen.
Configuration
Standard configuration: host, professional software, communication cable, micro printer, special sampler, vacuum grease, fast quantitative filter paper, vacuum pump, Temperature control device
Optional parts: sampling blade, vacuum pump oil, humidity generator
Remarks: The air source inlet of this machine is Ф6mm polyurethane pipe; the air source and distilled water are provided by the user.
Specifications
| Test Range: | 0.1 ~ 10,000 cm³/m²•24h •0.1MPa (Routine) |
|---|---|
| . | Upper limit is not less than 600,000 cm³/m²•24h •0.1MPa (extension volume) |
| Temp. Control Range | 10ºC~60ºC |
| Temp. Control Accuracy | ±0.1ºC |
| Vacuum Resolution: | 0.05Pa |
| Vacuum Degree: | <20Pa |
| Specimen Size: | Φ93mm |
| No. of Specimens: | 3 pieces (independent data respectively) |
| Transmission Area: | 33.18cm² |
| Test Gas: | O2, N2 and CO2, etc.(Users provide gas source themselves) |
| Test Pressure: | -0.1MPa ~ +0.1MPa |
| Pressure of Gas Source: | 0.4MPa~0.6MPa |
| Inlet Size: | Φ6mm polyurethane pipe |
| Dimensions: | 600mm (L)×475mm (B)×450mm (H) |
| Power: | AC 220V 50Hz |
| Net weight: | 75kg |
Applicable standards
ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A